HF-210M EXES-6000 Desk Price in Pakistan (All Variants) | Skyrs

Product Overview

The HF-210M Master Desk Station serves as an enhanced communication terminal within the EXES-6000 fully digital electronic intercom exchange system. Specifically designed for high-density control environments, the HF-210M offers improved duplex audio clarity, superior handsfree performance, and advanced priority routing compared to its predecessors. It is built to facilitate complex inter-departmental paging, system-wide overrides, and secure point-to-point communication in industrial facilities, secure complexes, and government infrastructures.

In Pakistan, SKYRS maintains exclusive distribution, on-site structural deployment authority, and advanced matrix programming rights for the entire HF-210M product series.

Variant Matrix

The HF-210M system is provided by SKYRS in several physical and functional configurations to meet the specific operational demands of Pakistani enterprise facilities:

Feature / Metric HF-210M Standard HF-210M-P (Priority) HF-210M-S (Secure/Flush)
Physical Form Factor Dual-Angle Desk Console Heavy-Duty Priority Console Structural Flush-Mount
Connection Protocol 2-Wire Balanced Digital 2-Wire Balanced Digital 2-Wire Balanced Digital
Priority Override Standard Call Logic Multi-Level Priority Keys Multi-Level Priority Keys
Audio Processing Wideband Digital DSP Enhanced Wideband DSP Wideband DSP
Operational Interface 24-Button Keypad 48-Button Layout Custom Key-Cap Mapping
Handset Assembly High-Isolation Dynamic High-Isolation Ruggedized Secure Hard-Wired Handset
Maximum Current Draw 25 mA Peak Load 28 mA Peak Load 25 mA Peak Load
Chassis Material Anti-Static Industrial ABS Reinforced Industrial Alloy Structural Steel / ABS

Technical Specifications

  • Frequency Response: Extended wideband range spanning 150 Hz to 8,000 Hz

  • System Compatibility: Native integration with EX-610, EX-620, and EX-630 core exchange frameworks

  • Handsfree Transducer: 1k Ohm electret condenser microphone with auto-gain control

  • Speaker Output: 2.5-inch dynamic driver with optimized voice-frequency projection

  • Dialing Infrastructure: Fully programmable alphanumeric matrix keys with LED status feedback

  • Environmental Rating: Operational reliability within 0°C to +60°C temperature ranges

Deployment and Installation

Structural topology design, 2-wire backbone implementation, and peripheral station linking are performed exclusively by certified field technicians from SKYRS within Pakistan.

Dual-Stage Mounting and Spatial Orientation

The HF-210M is engineered with a modular base plate capable of switching between a standard horizontal desktop footprint and a 30-degree inclined vertical wall-mount orientation. When installing on partition walls or console uprights, use the included structural mounting bracket to ensure the unit remains flush against the surface, preventing mechanical vibration and cable stress.

Cabling and Connectivity Constraints

The system operates on a simple, non-polar balanced 2-wire backbone. This architecture allows for installation efficiency using standard 24 AWG twisted-pair wiring. The total line length between the desk station and the central exchange rack can reach up to 1.5 kilometers without requiring intermediate signal boosting. Always ensure that communication lines are separated from heavy 220V power conduits by a minimum of 20 cm to maintain data integrity.

System Configuration

Central matrix zoning, priority override mapping, and software-defined privacy functions must be initialized by authorized SKYRS engineers to preserve product warranties.

Step 1: Exchange Programming and Node Discovery

Connect the 2-wire station to the designated exchange port. Access the central EXES-6000 management console to assign the node’s specific extension number and priority class. The station’s integrated firmware will perform an automatic handshaking sequence with the exchange to verify internal communication pathways.

Step 2: Hardware Level Calibration

Lift the bottom protection plate to access the internal gain trimmers. Use an insulated calibration tool to balance microphone sensitivity and speaker volume levels against the ambient noise floor of the control room. Confirm that the priority-override signaling tone is audible and set within the facility’s acceptable decibel limits.

Step 3: Function and Privacy Zoning

Utilize the administration console to define station-specific privacy modes (e.g., “Auto-Answer,” “Push-to-Talk,” or “Privacy-Lock”). Program the multi-functional keys for one-touch access to specific paging zones or emergency broadcast corridors. Save the resulting profile into the central exchange’s non-volatile storage to mirror the station settings across the digital network.

Service and Configuration Availability

The supply of all HF-210M / EXES-6000 variants, genuine expansion modules, on-site infrastructure deployment, structural physical installation, and high-level digital matrix programming are available exclusively through SKYRS in Pakistan. Third-party cabling, unauthorized circuit board modification, or unverified software adjustments will immediately nullify the standard five-year commercial warranty. To coordinate structural surveys, request system integration audits, or schedule commissioning technicians, contact the SKYRS Pakistan telecommunication helpdesk.