H004896R TOAlert EverAlert PoE Relay Price in Pakistan | Skyrs

TOA H004896R TOAlert / EverAlert Power over Ethernet (PoE) Relay Official Technical Data Sheet & Automation Integration Framework

The TOA H004896R is an ultra-compact, network-powered IP relay controller designed to execute automated scheduling and emergency event triggers within the TOAlert / EverAlert notification ecosystem. Drawing both operational power and synchronized timing commands over a single standard Ethernet line, this specialized device provides a precision physical contact-closure output to orchestrate low-power analog signaling hardware—such as facility bells, industrial horns, synchronized security strobes, and perimeter lock systems. It is engineered for seamless operation inside educational centers, factory floors, and corporate office layouts across Pakistan.

Technical Specifications

Parameter Specification Details
Primary System Role Network-driven timed relay output controller for low-power signaling
Power Input Requirement Power over Ethernet (PoE) via standard 802.3af switch port or standalone injector
Network Interface Port 10/100 Mbps Ethernet connection, RJ-45 standard interface
Primary Relay Output 1 Ch Normally-Open (NO) clean dry contacts (Normally-Closed NC available via custom order)
Relay Contact Ratings 2 A at 30 V DC / 0.5 A at 120 V AC
Active Loop Duration Programmable momentary closures spanning 1 to 59 seconds
Continuous Control Supports latching operation via distinct real-time network “ON” and “OFF” commands
Diagnostic LED Matrix

Red: Attempting sync (flashing) / Sync failure (solid)


Orange: Acquiring local IP address (DHCP sequence)


Green: Successful network sync & active operation

Management Software Web-based inCloud Management Portal or localized Network Clock Connect application
Scheduled Event Memory Up to 100 autonomous scheduled trigger blocks via local configuration tool
Dimensions (Overall) 109.5 (W) × 57.15 (H) × 22.2 (D) mm (Approx. 4.31”W × 2.25”H × 0.875”D)
Chassis Weight 68 grams (0.15 lbs) — low-profile lightweight footprint
Environmental Range Operational Temperature: 5 °C to 55 °C (41°F to 131°F); Humidity: 0% to 95% RH

System Variants and Provisioning Profiles

The underlying core microprocessing board is physically identical, but SKYRS provisions and maps the hardware firmware into distinct functional variants to complement localized facility automation designs across Pakistan:

  • H004896R-SCHED (Automated Timing Variant): Optimized explicitly to store local shift change or class period bell schedules (handling up to 100 unique localized intervals), functioning reliably even during momentary internet drops.

  • H004896R-EMERG (Visual Strobe Integration Profile): Customized to interface directly with industrial 12V/24V visual strobe networks, instantly initiating flashing warning runs when triggered by high-priority cloud emergency codes.

  • H004896R-NC (Special Order Secured Variant): Re-engineered with hardware-inverted Normally-Closed (NC) structural logic circuits, ideal for electronic security door releases or fail-safe industrial control loops.

Deployment and Installation Guide

Pre-Installation Site Checklist

  • Verify that the secondary signaling target (e.g., electronic horn or strobe lighting circuit) does not pull more than the 2A at 30VDC hardware limit.

  • Drop a dedicated Cat5e or Cat6 data line from a PoE-enabled local network area switch within standard distance limitations.

Physical Installation Steps

  1. Device Surface Mounting: Secure the compact H004896R chassis inside an auxiliary equipment cabinet, directly behind a display assembly, or directly to an electrical utility board using double-sided high-bond mounting tape or low-profile framing screws.

  2. Low-Voltage Output Wiring: Run a two-conductor signaling line from the dry-contact terminal blocks on the H004896R out to your target device’s triggering input loop (such as a school bell chime panel).

  3. Network Connection: Connect your active PoE network patch line directly into the RJ-45 socket port.

  4. Diagnostic Verification: Monitor the front-panel LED indicators immediately on connection. The orange light will flash while negotiating a local DHCP network address, turning into a solid green LED to confirm a successful network handshake and server sync.

Configuration Guide

System automation programming and zone group assignments can be completed using decentralized local applications or centralized enterprise web panels.

On-Demand Local Setup via Network Clock Connect

  1. Launch the Network Clock Connect utility software on a management computer connected to the matching network subnet segment.

  2. The application will scan the local network and discover the relay’s unique MAC address footprint.

  3. Use the integrated Event Editor screen layout to set up customized action lists (defining specific times, weekly days, and loop closure times from 1 to 59 seconds) and push the operational rules directly onto the device’s local non-volatile memory block.

Centralized inCloud Portal Automation

  • Device Enrolment Mapping: Log into your secure corporate cloud management portal dashboard and input the unique serial reference keys of the relay unit. Assign the hardware profile to a specific geographical zone matrix (e.g., “Factory Floor Zone 3”).

  • Mass Notification Overrides: Link the relay behaviors to emergency alert scenarios. Program your parameters so that triggering a severe event (such as an industrial hazard or site lockdown profile) overrides everyday schedules, forces an active “ON” loop state to spin up local warning sirens, and maintains the circuit block until an administrative clearance instruction is broadcast.

Local Procurement and Availability

Notice: The TOA H004896R TOAlert / EverAlert PoE Relay along with all project licensing profiles and custom-order inverted circuit assemblies are available and supported exclusively through SKYRS within Pakistan.

SKYRS delivers turn-key commercial automation platform designs, comprehensive multi-year official physical hardware warranties, and certified remote or on-site field engineering deployment assistance across all national markets.